Industrial Electrical Equipment & Power System

GROUND POWER UNIT FOR AIRCRAFT ELECTRICAL SYSTEMS/Saves jet fuel by supplying electricity for aircraft/Self Propelled Type,Truck Mount Type/90kVA,120kVA,180kVA(new)

Stable electric supply for various internal electrical systems of a airplane is very significant especially while engine stopped. SINFONIA GPU, which manufactured with accumulated experiences since 1983, reliably supply stable electricity for maintenance of such as measuring gauges, and lador, or engine starting up of aircraft, as a result, speedy and energy efficient operation is realized.

Features

  • Installed fuel saving engine
  • Durable, and long life structure
  • Pursuite usability by placing cable storage on both sides of body
  • Cutting edge technologies with accumulated experiences of over 30 years
GPU Product Range
  AC DC
90kVA 120kVA 180kVA 800A
Engine 6-Cylinder Water-cooled Diesel 6-Cylinder Water-cooled Diesel 6-Cylinder Water-cooled Diesel 4-Cylinder Water-cooled Diesel
Rated Output 90kVA 120kVA 180kVA 800A 1hour
Rated Voltage 115 / 200V 115 / 200V 115 / 200V 28V
Rated Frequency 400Hz 400Hz 400Hz -

Overload Capacity

125% 5min 125% 5min 125% 5min 1400A 1min
Power Factor 1 ~ 0.8 Lag 1 ~ 0.8 Lag 1 ~ 0.8 Lag -
Voltage Regulation ±1% ±1% ±1% ±0.8V
Frequency Regulation ±1.25% ±1.25% ±2Hz -
Protection (Example) Over Current, Over Voltage, Low Voltage, Over Frequency, Low Frequency, Low Oil Pressure, Coolant Water Temp Rise Over Current, Over Voltage, Reverse Current, Low Oil Pressure, Coolant Water Temp Rise
Mount Type Trailer Mounted / Truck Mounted
  AC/DC
90kVA/800A 120kVA/800A
Engine AC DC AC DC
6-Cylinder Water-cooled Diesel 6-Cylinder Water-cooled Diesel
Rated Output 90kVA 800A 1hour 120kVA 800A 1hour
Rated Voltage 115 / 200V 28V 115 / 200V 28V
Rated Frequency 400Hz - 400Hz -

Overload Capacity

125% 5min 1600A 1min 125% 5min 1600A 1min
Power Factor 1 ~ 0.8 Lag - 1 ~ 0.8 Lag -
Voltage Regulation ±1% 26 ~ 29V ±1% 26 ~ 29V
Frequency Regulation ±1.25% - ±1.25% -
Protection (Example) Over Current,
Over Voltage,
Low Voltage,
Over Frequency,
Low Frequency,
Low Oil Pressure,
Coolant Water Temp Rise
Over Voltage,
Element Temp Rise
Over Current,
Over Voltage,
Low Voltage,
Over Frequency,
Low Frequency,
Low Oil Pressure,
Coolant Water Temp Rise
Over Voltage,
Element Temp Rise
Mount Type Trailer Mounted / Truck Mounted

*The Specifications above may be changed without notice